Report No.: 300-ELAB-2381-EPA
Date: 06.09.2019
Initials: JSA/MGJN
Page 14 of 25
300-ELAB-2381-EPA
Summary of test fuel load properties
Core 1
Core 2
Core 3
Remainder
1
Remainder
2
Remainder
3
HF mass (kg)
0,458
0,469
0,451
0,582
0,348
HF moist. (% DB)
20,4
23,8
20,5
20,9
20,3
MF mas (kg)
0,555
0,557
0,549
0,399
0,635
MF moist. (% DB)
19,9
21,6
19,9
20,0
19,4
Dummy HF mas
(kg)
0,447
0,457
0,461
0,603
0,339
Dummy HF moist.
(% DB)
20,6
20,3
21,4
19,4
20,1
LF mass (kg)
0,547
0,572
0,576
0,418
0,693
LF moist (%DB)
22,1
22,6
21,5
20,4
20,9
Please find the fuel load calculations enclosed in appendices 5-8
Example of batch of firewood
Remarks
The certification tests were accomplished in accordance with the manufacturers written test
procedure (please find enclosed in appendix 9), the ASTM E3035-15 Cordwood test standard, the
EPA ALT125 letter and the ASTM E2515-11 dilution tunnel and sampling standard.
Start-up operation
The Morsø 6100B stove has an integrated air control system offering control of all the combustion
air supplied by means of a unitary control lever. For start-up, the lever is set in the left-most
position, giving maximum combustion air.
Please find a detailed description of the start-up procedure in the manufacturers test procedure
(appendix 9)