Report No.: 300-ELAB-2381-EPA
Date: 06.09.2019
Initials: JSA/MGJN
Page 21 of 25
300-ELAB-2381-EPA
Data, test run 2 Medium Fire test 20. January
Parameter
Value
Unit
Pitot factor (F_p)
0,9540
Dynamic pressure duct, Pd
27,3
Pa
Static pressure duct, Ps
125,7
Pa
Date of testing
20-02-2019
dd-mm yyyy
Start of test
12:18:20
hh:mm:ss
End of test
14:04:20
hh:mm:ss
Test duration
01:46:00
hh:mm:ss
Mean stove surface temperature at the start
NA
°C
Kindling and Start-up fuel load
NA
kg
Start-up fuel moisture
NA
% DB
Test fuel load
2,695
kg
Test fuel moisture
22,3
% DB
Resulting burn rate
1,25
kg (dry
matter)/h
Particulate emission rate, first hour
0,81
g/h
Particulate emission rate, overall
0,66
g/h
Sampled gas volume (nl), train 1
701,9
Nl
Captured pm mass, train 1
1,5
mg
Sampled gas volume (nl), train2
704,8
Nl
Captured pm mass, train 2
1,5
mg
PM mass total (average)
1,173
g
Relative deviation in pm emission, train 1 to train 2
0
%
Absolute deviation in pm emission, train 1 to train 2
0
g/kg (dry
matter)
Mean flow rate probe, train 1
6,45
m/s
Mean flow rate probe, train 2
6,48
m/s
Mean flow rate duct
6,58
m/s
Flue gas temperature (mean)
161
°C
Flue draught (mean)
12
Pa
Parameter
Start value
End value
Units
Ambient temperature
24,3
24,8
°C
Relative humidity
19,3
29,2
%
Barometric pressure
1015,0
1015,4
hPa
Draft in front of the test rig
0,09
0,08
m/s
Flue gas temperature
159
111
°C

Related product manuals