Report No.: 300-ELAB-2381-EPA
Date: 06.09.2019
Initials: JSA/MGJN
Page 22 of 25
300-ELAB-2381-EPA
Data test run 3 Dummy High Fire 21. February
Parameter
Value
Unit
Pitot factor (F_p)
0,9475
Dynamic pressure duct, Pd
27,5
Pa
Static pressure duct, Ps
125,9
Pa
Date of testing
21-02-2019
dd-mm-yyyy
Start of test (from cold)
12:10:00
hh:mm:ss
End of test
13:36:55
hh:mm:ss
Test duration (Cold start + High Fire)
1:26:55
hh:mm:ss
Mean stove surface temperature at the start
23,2
°C
Kindling and Start-up fuel load
1,141
kg
Start-up fuel moisture
20,1
% DB
Test fuel load
2,307
kg
Test fuel moisture
21,0
% DB
Resulting burn rate
1,67
kg (dry
matter)/h
Particulate emission rate, first hour
NA
g/h
Particulate emission rate, overall
NA
g/h
Sampled gas volume (nl), train 1
NA
Nl
Captured pm mass, train 1
NA
mg
Sampled gas volume (nl), train2
NA
Nl
Captured pm mass, train 2
NA
mg
PM mass total (average)
NA
g
Relative deviation in pm emission, train 1 to train 2
NA
%
Absolute deviation in pm emission, train 1 to train 2
NA
g/kg (dry
matter)
Mean flow rate probe, train 1
NA
m/s
Mean flow rate probe, train 2
NA
m/s
Mean flow rate duct
NA
m/s
Flue gas temperature (mean)
162
°C
Flue draught (mean)
13
Pa
Parameter
Start value
End value
Units
Ambient temperature
24,1
24,7
°C
Relative humidity
35,9
36,0
%
Barometric pressure
1016,2
1016,9
hPa
Draft in front of the test rig
0,04
0,06
m/s
Flue gas temperature
22,7
169
°C