Stove type Behind the
stove (A)
To the sides
of the stove (B)
Above the Stove Clearances to
furniture furniture
Morsø 7110
uninsulated flue
300 mm 500 mm 500 mm 1000 mm
Morsø 7110
insulated flue
Morsø 7140
uninsulated flue
150 mm
300 mm
500 mm
500 mm
500 mm 1000 mm
500 mm 1000 mm
Morsø 7140
insulated flue
150 mm 500 mm 500 mm 1000 mm
Minimum clearances to combustible surfaces:
On the floor
National and Local Building Regulations must again be observed when considering the type,
thickness and area of the hearth to be used in the installation. The hearth temperature under
safety test was less than 65°C.
One should of course always make certain that the underlying floor surface can bear the weight
of the stove.
Clearances to Furniture
The clearance requirement from the stove to any furniture should be no less than 1000 mm. It
is always necessary to assess whether or not any furniture or other objects situated close-by
can be affected by heat, i.e. dried out.
The distance to any combustible material in front of the stove is minimum 1000 mm.
The surface of a wood burning stove gets extremely hot when used and therefore special at-
tention to safety is paramount, especially where children or the infirm are present.