Note:
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof
cover
Fresh Air Inlet
Unless there is deemed to be sufficient ambient leakage of air into the room via doorways,
windows and the like, a dedicated fresh air inlet will be needed. This inlet should have 2
square inches (1250 square mm) of free air space. This is particularly important where the
room is well sealed, or where an extractor hood or ventilation system disturbs the natural air
pressure. Such an inlet should not be on a wall that is usually subject to negative pressure
from normal wind pattern. Avoid placing the inlet directly across the room from the stove,
thus causing a cold air draft.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED (I.E., DO NOT CUT THROUGH FLOOR JOIST, WALL STUD,
CEILING TRUSS, ETC.)
DO NOT USE A GRATE TO ELEVATE FIRE - BUILD FIRE DIRECTLY ON HEARTH.