June, 2005 6880309N62-C
6-2 VHF Troubleshooting Tables: Troubleshooting Table for Receiver
No Audio
1. Synthesizer out of lock Verify U201-4 is at 3 V dc. Troubleshoot synthesizer/VCO 
circuits.
2. Defective IFIC Verify audio is present  at U51-8. Check Q70, Y70, U51.
3. RX audio buffer fault Verify audio is present  at U451-2. Check U510 and associated 
parts.
4. ASFIC fault Verify audio is present at U451-41. 
Verify U451-14 is high.
Check squelch setting, PL/DPL 
programming. Troubleshoot/
replace U451.
5. Audio PA fault Verify U490-1 is <0.2 V dc.
Verify audio is present at U490-5 
and 8.
Check Q490.
Check/replace U490.
6. Defective speaker Verify audio is present at speaker 
terminals.
If not, check continuity of J471-2 
and 3. Check J491. If yes, 
replace speaker.
No Receive 
(squelch noise 
present)
1. No first injection Check that RF level at T42-6 is 
approx +6 dBm.
Check that RF level at U251-8 is at 
least -8 dBm.
Check injection filter C40-44, 
L40-41. 
If yes, check Q280 and associ-
ated parts. If no, check U251 
and components on pins 5 and 
6.
2. No 5R source. Verify U401-49 is high in RX.
Verify Q311 gate is 0 V dc in RX
Verify Q311 drain is 5 V dc in RX.
Check/replace U401
Check/replace Q313.
Check for shorts, check/replace 
Q311.
3. Harmonic filter or 
antenna switch fault
Apply on-channel 100 mV RF signal 
at antenna port. Verify RF level at jct. 
C1/C2 per schematic.
Check TX harmonic filter, D120-
121. Should be 0 V dc on D120-
121.
4. Back end fault Apply on-channel 100 mV RF signal 
at antenna port. Measure RF levels 
from FL51 through U51.
Check components prior to loss-
of-signal point.
5. No second injection Measure RF level at U51-3, verify 
approx. 280 mV rms.
If dc voltages at U51-3 and 4 
are OK, check Y51 and associ-
ated parts. If not replace U51.
Table 6-1.  Troubleshooting Table for Receiver  (Continued)
Symptom Possible Causes Procedure Corrective Action