13
6. Operation Instruction
Turn the cleaning pump on pressing pump switch. Wet the sink, parts to be cleaned
and any brushes prior to cleaning; this will prevent grease and dirt from sticking to the
surfaces.
The maximum load of 100 kg must not be exceeded!
Depending on the positioning of the 3-way control valve, cleaning can occur via:
Washing by means of a versatile jointed hose with nozzle.
Cleaning with low-through cleaning brush.
In middle position both outlets are open.
After the cleaning process has ended switch o the pump again..
The unit is equipped with an electronic timer which stops the pump automatically after
30 minutes. The timer range can be set between 5 and 60 minutes.
Note: Any parts susceptible to corrosion should not be left in the sink after cleaning.
As with all parts cleaners, excess grease and oil should be disposed of prior to washing.
Do not use this unit as a waste dump. Do not introduce disinfectants, solvents, brake
luid, engine coolant, chlorinated, acidic or alkaline solutions into this system. Do not
add water!
The optimal temperature for the activity of microorganisms and therefore for the
breakdown of oil is approx. 3841 °C. Therefore leave the unit always switched on.
For optimal activity of microorganisms and thus of the breakdown of oil, it is essential
that the microorganisms have a supply of oxygen. This is why an air sprinkler has to
be permanently switched on, which guarantees the required oxygen supply for the
microorganisms. If the unit is switched o, or fails because of a defect, the result is that
the microorganisms become inactive.
If the unit is to be idle for more than two weeks, it is recommended to turn the unit o.
Make sure the surface of the liquid is not covered with oil. If necessary skim o or absorb
any accumulation of oil.