15
Filters
The Motul BioClean parts washer is equipped with three-part iltration system: a coarse
ilter on the surface of the sink, underneath a mesh ilter for iner material or other
impurities and then a magnet. It is recommended to clean these ilters and the magnet
outside the parts washer daily. Take the ilters and the magnet out of the sink, wash out
and clean with water. Underneath the
sink a ilter bag can be installed,
check this regulary and empty or
change if necessary.
Liquid Filter (optional)
The ilter housing can be installed on the right back of the unit. It is to be checked
weekly and if necessary changed. Release the ilter cartridge by turning anti-clockwise.
Remove the ilter and put in a new one. When screwing on the ilter cartridge take care
that it its correctly. Alternatively a reusable nylon ilter can be installed.
Drain lap
This unit is equipped with a lap located underneath the coarse ilter and magnet to slow
down evaporation, if too much evaporation occurs, verify that lap moves freely.
Annual maintenance
It is recommended that your Motul BioClean parts washer is inspected and cleaned
annually to perform at optimal eiciency. Depending on the application non-digestible
matter can accumulate as sludge at the bottom of the tank over time, which can nega-
tively aect the bioremediation activity.
To facilitate the removal of the sludge unplug unit. Connect a hose to drain valve and
fully open the valve, wait a few seconds and then close the valve. Repeat these steps
3times to remove most of the sludge.
Alternatively open the sink and empty the unit from all the cleaning solution using a
hand pump until the sludge becomes visible. If cleaning solution is still cleaning well,
save it for re-use. Remove the sludge and clean the tank walls and pumps. After that
reill the unit. Visually inspect pumps, tubing and connections. Replace parts that show
excessive wear.
Reorders:
352703 Filter bag polypropylene, needle felt 25m