— 4 — — 5 — — 6 —
7. Environmental Specifications
Power Requirements Power input: 9-30 VDC
Power consumption 300 mA @ 9 VDC (max.)
Operating Temperature 0 to 55°C (32 to 131°F),
5 to 95% RH
Storage Temperature -20 to 80°C (-4 to 185°F),
5 to 95% RH
Magnetic isolation Built-in 1.5 KV
Serge protection 15 KV ESD for all signals
Regulatory Approvals FCC Class B, CE Class B,
CUL, TÜV
8. Development Environment
Development Platform Windows 95/98/NT/2000/XP
Compiler/Linker Borland Turbo C 2.01 included
with license card (SDK is
compatible with Borland Turbo C
2.x, Borland C 3.x)
Development Console Ethernet
Software Download Tool SDK Manager
Debug Tool SDK Manager
Library Serial port,
Simplified Socket,
BSD Socket,
System,
Flash Access,
Debugging,
STD C libraries
User Program Space Total of 64 KB for code and data
Data
Storage 32 KB Read/Write on Flash ROM
Max. TCP Sessions 10 sessions
Max. Thread Single task
Intellectual Property Protection Software key protection for user
program
Note: Refer to the User’s Manuals on the Documentation and Software
CD for more detailed information about this product.
Copyright 2004
Moxa Technologies Co., Ltd.
All rights reserved.
Reproduction without permission is prohibited.
Tel: +886-2-8919-1230 www.moxa.com
Fax: +886-2-8919-1231 support@moxa.com.tw