● dhcp-timeout is the time the MAGBES tries to retrieve IP settings via the DHCP. If this time elapsed
after valid link detection, the MAGBES uses the dhcp-fallback IP Address.
● dhcp-fallback is the IP Address which will be used after the dhcp-timeout has elapsed.
● The value of the <ip-settings> tag is the IP Address.
6.2.2.3 Jumbo Frame
<jumbo-frame>on</jumbo-frame>
The <jumbo-frame> tag switches the jumbo frame support “on” or “off”
6.2.2.4 Telnet CLI
<telnet-cli>on</telnet-cli>
The <telnet-cli> tag switches the telnet based command line interface “on” or “off”
6.2.2.5 Web UI
<webui>on</webui>
The <webui> tag switches the Web based user interface “on” or “off”
6.2.2.6 Hostname
<host-name>Magbes</host-name>
The <host-name> tag contains the host name.
6.2.2.7 Location
<location></location>
The <location> tag contains the location string.
6.2.2.8 Password
<password>bFdVfUzG29dvZJgG+doDfQ==</password>
The <password> tag contains the password. The password is a base64 coded encrypted string.
Note:
There exist no external tool to decrypt or encrypt the password. The only way to get an encrypted
string of new password, is to enter the new password in the MAGBES and download the configuration
file.
6.2.2.9 Login Timeout
<login-time>15</login-time>
The <login-time> tag contains the login timeout in Minutes.
6.2.3 Port section
Main tag:
<port-configuration>
This section contains the settings for the ports:
6.2.3.1 Port
<port id="0" duplex="off" flow-control="off" downshift="off" snmp-
trap="off">auto</port>
The <port> tag contains the settings of a port:
● id is the port number. Allowed values are “0” to “4”
● duplex is the duplex setting of the port. Allowed values are “on” or “off”. Note: If the port is set to
auto, this setting is ignored.
● flow-control is the flow control setting of the port. Allowed values are “on” or “off”
● downshift is the downshift setting of the port. Allowed values are “on” or “off”. Note: This setting is
only relevant if the port is set to auto.
● snmp-trap enables/disables the SNMP misc trap on SFP with diagnostic functions. Note: On Copper
port this setting is not allowed.
● The value of this tag is the speed setting of the port. Allowed values are disable, 10M, 100M, 1G and
auto.
2012 by MPL AG 71 MEH-10134-201 Rev. D