Remove Suction Protection Cap.
Fit the Filter to the collection tray and slide tray up to
clip into position.
Installing
Insert and slide to lock pump module into
position.
Make sure the end of the drain hose is within the tray
and ensure flow is unrestricted.
Testing
WARNING! Thepumpisliveduringtesting,other
powercircuitsmayalsobelive.
Testthepumpoperationbyslowlypouringwaterinto
theairhandlercondensatecollectiontray,ensuringthe
waterdrainsintothepumpcollectiontraywithout
restriction.
Continuetopouruntilthewaterbridgesthesensor
andthepumpwillbegintopumpawaythewater. The
pumpwillstopautomatically.Repeatuntilwatercan
beobservedenteringthefinaldrain.
Checkforleaks.
FittheCover.