5
2-5 Measurement Specifications
Accuracy are
•±
(
of reading
number of digits) at 18
to
28
( 64
to 82
) with relative humidity to 80
.
TRUE power & Apparent power measurement
Input Resolution Accuracy
Frequency
range
Overload
protection
V<130V , A<150A
V>130V , A<150A
V<130V , A>150A
0.01
±
(2%+5)
V>130V , A>150A 0.1
±
(2%+1)
45Hz
500Hz
600V/1100A
DCA
Range Resolution Accuracy Overload protection
1000A 0.1A
±
( 1.5% + 5)
1100A
ACA
Range Resolution Accuracy
Frequency
range
Overload
protection
1000A 0.1A
±
( 1.5% + 5)
45Hz
500Hz
1100A
Crest factor : < 3 for stated accuracy
DCV
Range Resolution Accuracy
Input
impedance
Overload
protection
600V 0.1V
±
(0.5% + 5)
1M
Ω
600V
ACV
Range Resolution Accuracy
Input
impedance
Frequency
range
Overload
protection
600V 0.1V
±
( 0.5%+5)
1M
Ω
45Hz
500Hz
600Vrms
Crest factor : < 3 for stated accuracy