MrCool DIY Specifications

General IconGeneral
Product TypeAir Handler
SeriesDIY
Phase1
Frequency60 Hz
RefrigerantR410A
Voltage208/230V
Cooling Capacity18, 000 BTU/h
Heating Capacity18, 000 BTU/h
HSPF Rating9

Summary

Safety Precautions

General Safety Guidelines

General safety instructions and symbol explanations for safe usage.

Installation and Operation Warnings

Critical warnings related to installation, electrical safety, and unit operation.

Operational Cautions and Notes

Cautions on operation and important notes regarding fluorinated gases.

Parts Overview

Indoor Unit Components

Diagram and labels for the indoor unit (air handler) and its parts.

Outdoor Unit Components

Diagram and labels for the outdoor unit (condenser) and its parts.

Accessories

Included Accessories

Detailed list of included accessories with quantities and visual references.

Optional Parts

List of optional parts that may be purchased separately for enhanced functionality.

Operating Instructions

Operating Temperature Ranges

Recommended temperature ranges for COOL, HEAT, and DRY modes.

Manual Operation

Instructions for operating the unit manually without the remote control.

Airflow Directional Control

How to adjust vertical and horizontal airflow direction for optimal comfort.

Operation Mode Selection

Guidelines for selecting and coordinating operating modes across multiple units.

Special Functions

Details on functions like Refrigerant Leakage Detection and Anti-Mildew.

Care and Maintenance

Cleaning the Unit

Procedure for cleaning the indoor unit with appropriate materials.

Cleaning Air Filters and Fresheners

Steps for removing and cleaning air filters and air freshener components.

Extended Non-Operation Preparation

Steps to prepare the unit for periods of extended inactivity.

Pre-Season Inspection

Checks to perform before resuming operation after a period of non-use.

Installation Diagram

Installation Safety Precautions

Important safety considerations for the installation phase.

Line Set Length Specifications

Specifications for maximum line set length and height difference.

Indoor Unit Installation

Selecting Installation Location

Guidelines for choosing an appropriate and safe location for the indoor unit.

Mounting Plate and Wall Hole

Steps for attaching the mounting plate and drilling the wall hole for piping.

Refrigerant Piping and Unit Mounting

Instructions for preparing refrigerant piping and mounting the indoor unit.

Outdoor Unit Installation

Selecting Installation Location

Guidelines for choosing an appropriate and safe location for the outdoor unit.

Install Drain Joint

Procedure for installing the drain joint for heat pump units.

Anchoring the Outdoor Unit

Instructions for anchoring the outdoor unit to the ground or bracket.

Refrigerant Piping Connection

Prepare and Unwind Line Set

Preparing the exterior wall hole and unwinding the refrigerant line set.

Connect Line Set to Indoor Unit

Detailed steps for connecting the line set to the indoor unit.

Torque Requirements

Specifications and procedures for tightening refrigerant line set connections.

Connect Line Set to Outdoor Unit

Detailed steps for connecting the line set to the outdoor unit.

Opening Refrigerant Valves

Procedure for opening the refrigerant valves on the outdoor unit.

Wrap Piping Connections

Steps for wrapping and insulating exposed refrigerant line connections.

Connect Drain Pipe

Connecting the drain hose extension to the drain pipe.

Electrical Connections

Electrical Work Regulations

Regulations and precautions for performing electrical work on the unit.

Wiring Diagrams

Diagrams illustrating electrical connections for different system configurations.

Connect MC Cables to Outdoor Condenser

Procedure for connecting the MC cables to the outdoor condenser unit.

Electrical and Gas Leak Checks

Electrical Safety Checks

Checks to confirm the unit's electrical system is safe and properly installed.

Gas Leak Checks

Methods for checking refrigerant piping connections for leaks.

Test Run

Pre-Test Run Checks

List of checks to perform before starting the unit's test run.

Test Run Instructions

Steps for conducting the test run and verifying system functions.

Troubleshooting

Common Symptoms and Causes

Table of common issues, their potential causes, and solutions.

Error Code Displays

Explanation of indoor and outdoor unit error codes and their meanings.

Troubleshooting by Error Code

Association of error codes with potential faulty parts.

Automatic Wiring/Piping Correction Function

Procedure for using the automatic wiring/piping error correction function.

EU Disposal Guidelines

Correct Product Disposal

Guidelines for the proper disposal of electrical waste and electronic equipment.