1. Heater intended application and technical data
The universal oil heater type MTM 52 is designed to heat up industrial
rooms not covered with central heating systems (workshops, car repair shops,
industrial shops, warehouses, storage buildings, basements, garages, etc.).
The stove can operate using most waste oils of mineral and plant origin,
e.g. engine, gear, hydraulic, fuel oil, with maximal density in temperature of 15°C
equal to 860 kg/m
3
and with ignition temperature exceeding 56°C.
DO NOT USE TRANSFORMER OIL AS THEY CAN CONTAIN SUBSTANCES
AFFECTING STOVE OPERATION AND USER HEALTH
TECHNICAL DATA
* Calorific effect specified for fuel with the following parameters:
calorific value = 42.6 MJ/kg.
density at temp. max. 15°C = 860 kg/cm
3
.
In case of higher parameters, the calorific effect can be
increased even up to 55 kW.
2. Storage environmental conditions
The universal oil heater type MTM 52 must be stored in the following conditions:
temperature from -20°C to 85°C
relative humidity < 85%
pressure < 1200 hPa
no dusting
environment free from chemical contamination.
3. Use environmental conditions
The universal oil heater type MTM 52 must be used in the following conditions:
temperature
relative humidity
pressure
IP protection level against environmental impact
good ventilation of the heated room.
device noise -
4. Safety aspects
It is inadmissible to use fuels other than specified in point 1. of the Original Manual.
In particular, it is forbidden to use such fuels as solvents or petrol!
All activities regarding operation of the device must be performed in protective
gloves and by a person trained for operation.
It is prohibited to put hands in the protective grids of the furnace or areas of the operating
fan.
It is necessary to ensure efficient ventilation of the heated room in order to avoid carbon
monoxide poisoning.
from 0°C to 30°C
< 85%
< 1200
hPa
IP21
not exceeding 70Db
Maximal thermal capacity* kW 52
Minimal thermal capacity* kW 30
Maximal fuel consumption l/h 5.2
Minimal fuel consumption l/h 3
Heated air flow m
3
/h 5500
Power supply V/Hz 230/50
Maximal power consumption W 300
Exhaust fumes outlet diameter mm 150
Device width cm 60
Device height cm 130
Device length cm 120
Device weight kg 120
TEMPLATE OF THE RATING PLATE
PLACED ON THE REAR ENCLOSURE OF THE DEVICE