7.21.3 Differential pressure gauge – Check
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Checking differential pressure gauge
1. Switch on fuel treatment system (→ Page 140).
2. Set the alarm points at the differential pressure gauge to zero.
Result: Alarm is issued after preset time.
3. Reset alarm points at pressure gauge for differential pressure.
MS150119/01E 2016-02 | Fuel Treatment System | 141
TIM-ID: 0000007737 - 006