Function
LIQUID IN THE LEVEL TUBE
The level tube (on the right hand side, viewed from the front) (27) shows
how much liquid there is in the tray. The tube should definitely not be full; this
means the tray is full of liquid.
1
-2cm (
1
/2 ") of liquid in the tube is ok. If the
tube is filled and no warning in the display it can be caused of some kind of
trouble with the float. Enter the service menu and check the liquid indicator
and sensor ( page 7). If the sensor dont indicate correct level, put the heater
in manual mode (high level) button B to increase the heat to max. When the
liquid is gone in the tube , empty the tray and clean the area around the float.
FLOAT FUNCTION
BioLet 55/65ai is equipped with a float in the tray. That will adjust the heat (capacity) in the toilet according to usage.
Therefore its very important to have a regular check of the tube (27) of the amount of liquid in the tray.
ADD EXTRA HUMUS STARTER
The compost should be porous and of moderately moist texture. Add humusstarter regularly, approx.
1
litre (quart) /
week. If the compost get wet and compact it is better to add humus starter then increase the heat, as long as the
liquid in the tube do not increase.
EXTRA GUESTS
Add a couple of litres (quarts) of humus starter.
Enter the manual mode by pressing button B for maximum evaporation.
LOW LOAD, STAND-BY MODE
The fan-motor will go into a stand-by mode if there is no liquid in the tray or if there is less then 6 visits per
24hours. The fan will automaticly be activated again if the liquid or number of visits increase.
MIXING
The waste and paper will be mixed into the compost when using the toilet,
the mixer-motor is activated automaticly after each visit.
The mixer-motor will also start automaticly every 2 hours.
EMPTYING
The general rule is to empty the tray when the compost level reaches the upper levelling arm (22a).
It will only take a few days after emptying before the tray is filled again. It should stay full for composting until
the next emptying.
The toilet also have an reading function for the compostlevel, the heaters will be activated and after 24h the
display will say "Empty Tray". To empty the tray do as follows:
1. Make sure there is no liquid in the level tubes on the right (27) or left hand (26) side. If there is liquid press
button B and set to "Max Heat" and wait until the liquid has evaporated.
2. Disconnect the power.
3. Remove the front cover (25) and the tube from the tray.
8