Page 3
2. General Notes
The MULTIGLOW CLASSIC II LPG is a Decorative Fuel Effect (D.F.E.) primary aerated
gas fire, designed to comply with BS EN 509:2000 and is intended for decorative use only.
It has been designed to operate on LPG Gas only and must be fitted on a non-combustible
hearth in a standard builders opening, with either a Class 1 (7”) or Class 2 (5”)
chimney/flue (subject to appliance size) and satisfy the ventilation requirements of BS 5871
– Part 3.
This appliance conforms to the relevant Safety Standards but during use, there are naked
flames and parts of the casing become hot.
If the appliance is fitted with a permanent guard (to BS 6778), no part of
the guard should be permanently removed so that access to the flame is
minimized, as it does not give full protection for young children, the
elderly or the infirm.
This appliance is not fitted with an integral guard. In normal use
consideration may be given to the use of a guard conforming to BS 6678
or BS 6539 such that the access to the flame is minimised and for the
protection of young children, the elderly or the infirm.
NOTE: The larger of the units manufactured have gas consumption similar to that of a
small boiler (i.e. 50,000 BTU). Therefore, it is essential that the gas supply
pipework be of a size that will allow for the correct flow rate (see TECHNICAL
DATA for required information). Ideally, the 8mm connection pipe to the burner
should be as short as possible and the maximum length should not be greater
than 1m. Also ensure that the isolating tap does not have a reduced bore.
NOTE: The Basket or Fret used with this appliance will become hot during use. Care
should be taken when operating the controls.
RCF Advice:
This product may use components containing Refractory Ceramic Fibres (RCF), which are
main-made vitreous silicate fibres. Excessive exposure to the fine dust of this material
may cause irritation to eyes, skin and respiratory tract.
Therefore during installation and servicing we recommend that you use a HEPA filtered
vacuum cleaner to remove any dust and soot accumulated in and around the fire before
and after working on the fire, to ensure that the release of fibres from these RCF articles is
kept to a minimum.
You should follow the normal hygiene rules of not smoking, eating or drinking in the work
area.
When replacing components containing Refractory Ceramic Fibres (RCF), we recommend
that the replaced items are not broken up, but are sealed within heavy duty polythene