EasyManua.ls Logo

MULTISPAN LC-2046 User Manual

MULTISPAN LC-2046
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PV = Process Value
SV = Set Value
LC-2046
LENGTH COUNTER
TECHNICAL SPECIFICATION
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(As per request)
Operating Temp.
0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
MECHANICAL INSTALLATION
TERMINAL CONNECTION
PROXY COLERS CODE
Page -1
AUXILIARY SUPPLY:
Supply voltage
Power consumption
(VA RATING)
Approx 4 VA @ 230V AC MAX
230V AC, 50Hz
Input (Start Pulse)
Display
Memory
Size
Keys
Counting Direction
Panel Cutout
Upper: 6 digit, 7 segment, 0.40” Red
Nonvolatile
Lower: 4 digit, 7 segment, 0.40” Green
72 (H) x 72 (W) x 60 (D) mm
SET/ENT, SHIFT, INC, RESET
68 (H) x 68 (W) mm
GENERAL SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
NPN/PNP Proximity
Micro Switch
UP/ DOWN
Reset Option
Front Panel Reset
Terminal Reset
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
Relay Type
Rating
1 nos.
1 C/O (NO-C-NC)
5A, 230V AC
Relay Output
+12V
OUTPUT
GND
Brown
Black
Blue
Red Green Black
Outline Dimension (mm)
Panel Cutout
Dimension (mm)
72
60
68
68
3
72
SET
ENT
RESET
R
LC 2046
MTR/MIN
1 2 3 4 5.6
1 2 3.4
230V AC
50Hz,4VA
NC
I/P
NPN
+12V
I/P
PNP
GND
NO
C
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
!
RESET
Made in India
www.multispanindia.com
TOTAL

Other manuals for MULTISPAN LC-2046

Question and Answer IconNeed help?

Do you have a question about the MULTISPAN LC-2046 and is the answer not in the manual?

MULTISPAN LC-2046 Specifications

General IconGeneral
BrandMULTISPAN
ModelLC-2046
CategoryCash Counter
LanguageEnglish

Summary

Technical Specifications

Input Specification

Details input types like NPN/PNP proximity and Micro Switch for triggering.

Display and Keys

Describes display characteristics and the function of control keys.

Dimensions

Specifies the unit's physical size and panel cutout dimensions.

General Specifications

Covers memory type, counting direction, and reset options.

Output Specification

Details the relay output type, rating, and number of contacts.

Auxiliary Supply

Outlines power requirements including voltage and consumption.

Environment Conditions

Operating Temperature and Humidity

Specifies permissible operating temperature and relative humidity ranges.

Protection Level

Defines the ingress protection rating for the front side of the unit.

Mechanical Installation

Outline Dimensions

Provides the external physical dimensions of the counter unit.

Panel Cutout Dimensions

Specifies the required size for mounting the unit in a panel.

Terminal Connections

Terminal Layout and Wiring

Illustrates the terminal connections for power, input, and output signals.

Front Panel Description

Display Elements

Identifies the components on the front panel display.

Key Operation Functions

Explains the functions of the keys in different operating modes.

Mechanical Installation Guidelines

Panel Preparation and Fitting

Instructions for preparing the panel cutout and fitting the unit.

Terminal Wiring Torque

Specifies the correct torque for terminal block screws.

Maintenance and Safety

Cleaning and Maintenance

Guidance on regular cleaning and maintenance procedures.

Safety Precautions

General safety instructions for operating personnel and the instrument.

Installation Guidelines

Wiring and Electrical Safety

Instructions for safe wiring, circuit breakers, and cable selection.

Environmental Storage

Recommendations for storing and using the instrument within specified ranges.

Warning Guidelines

Risk of Electric Shock

Warnings and precautions related to electrical hazards during wiring.

Electromagnetic Interference

Advice on reducing EMI through proper wiring and cable use.

Parameter Setting

Setting Total Length

Procedure to set the total length value for material counting.

Setting Time Value

Procedure to set the time value, affecting relay operation.

Setting Diameter Value

Procedure to set the roller diameter for accurate length calculation.

Setting Speed Selection

Configuring the speed range for meter/minute display.

Setting Decimal Point

Configuring the decimal point position for displayed values.

Setting Count Direction

Selecting the counting direction (Up or Down).

Setting PPR

Configuring pulses per revolution for accurate measurement.

Working and Notes

Display Indications

Explains how the upper and lower displays indicate length and speed.

Relay Operation Logic

Describes relay energizing and de-energizing based on set length and time.

Power Failure Behavior

Details how the counter resumes operation after a power interruption.

Proxy Alignment

Sensing Area Requirements

Guidance on ensuring proper sensing area size for the proximity sensor.

Related product manuals