EasyManua.ls Logo

Munster Simms Engineering Ltd. Whale V-PUMP MK.6 User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
V- PUMP MK.6
GP0650
Also Service Kits/Assemblies:
AK0618 & AS0627
Read carefully before
installation and use.
To the fitter: Check that
the product is suitable for the
intended application, follow
installation instructions and
ensure operating instructions
are passed onto the end user.
To the User: Read the
following instructions care-
fully.
Application
This product is designed for
use as a domestic freshwater
& saltwater hand pump in
caravans and boats. Use for
any other purpose or with
any other liquid, is not rec-
ommended and is entirely at
the user`s risk.
This pump may also be used
in conjunction with an in-line
pump, or as a back up to a
submersible pump.
Installation
Choose an installation where
the pump can be operated
comfortably. Note: The
maximum reach of the outlet
spout is 115mm (4½")
Once you have found your
location, drill a 25mm (1")
hole, fit pump, position base
and secure using the two
wood screws.
Hose connection
If using Whale Water System
15 pipework WX1504 equal
straight will fit directly onto
the pump, if using
System12 use WX1504 &
WS1215 stem reducer 15mm-
12mm alternatively you can
use 13mm (½") flexible
tubing.
The height of the pump
maybe adjusted by loosening
screw (A).
Operation
To operate pump the handle
up and down, water will be
discharged on both strokes.
Maintenance
Regular inspection of valves
and seals is recommended
with cleaning and replace-
ment of components as
necessary.
To dismantle pump:
Unscrew head and spout from
Barrel, pull plunger and head
from barrel. Unscrew plunger
cup seat from plunger rod and
pull head and spout from
plunger rod. To remove U-
Packing seal from head,
carefully ease cap (B) off using
a flat screw driver, replace U-
Packing seal making sure to fit
the new seal the same way
round as old seal (U facing
down).
Note: Replacing O-Ring (C)
may prove difficult to remove
and we recommend that it is
not replaced unless a leak is
observed under the head.
Replace cup washer, O-Ring
(D) and buffer on plunger cup
seat.
Reassemble making sure that
cap is securely pushed back
into position
To replace bottom valve (E)
unscrew base from barrel of
pump. A service kit AK0618
is available from dealers.
Contact Whale for MK5 V-
pump drawing or instruction.
NOTE: For winter storage,
ensure that the pump is
drained completely to avoid
frost damage.
S ub mer si bl e
921
Question and Answer IconNeed help?

Do you have a question about the Munster Simms Engineering Ltd. Whale V-PUMP MK.6 and is the answer not in the manual?

Munster Simms Engineering Ltd. Whale V-PUMP MK.6 Specifications

General IconGeneral
BrandMunster Simms Engineering Ltd.
ModelWhale V-PUMP MK.6
CategoryWater Pump
LanguageEnglish

Summary

Product Usage and Application

Intended Use

Details the pump's design for domestic freshwater and saltwater hand use in caravans and boats.

Alternative Applications

Mentions compatibility with in-line pumps or as a backup to submersible pumps.

Installation and Operation

Installation Steps

Covers selecting location, drilling, fitting, and securing the pump using wood screws.

Hose Connection Types

Explains connections for Whale Water System 15 pipework and flexible tubing.

Pump Operating Instructions

Describes the handle action for water discharge on both strokes.

Maintenance and Troubleshooting

Routine Maintenance

Recommends regular inspection, cleaning, and replacement of valves and seals.

Pump Dismantling Guide

Step-by-step instructions for disassembling the pump for repairs or part replacement.

Part Replacement Advice

Guidance on replacing specific seals, O-rings, washers, and the bottom valve.

Winter Storage Precautions

Advises draining the pump completely to prevent frost damage during winter.

Helpful Hints and Warranty

Pump Performance Troubleshooting

Addresses issues like slow priming and the pump not pumping, suggesting checks for worn parts or leaks.

Warranty Information

Details the 1-year guarantee against defects and the conditions for repair or replacement.