8. Wiring diagrams
GRY-D 15HU / 20WU-HU / 28WU / 40WU
L
N
TR
black
black
FS
white
whiteblack
M
black
EARTH
TR
SV
PHOTO
PHOTO
MT
INT 1
black
black
IN
INT 2
P
PA
FC
black
N
N
L
N
N
black
green
green
FC Photocell
FS
Fuse
IN
Switch
M
Motor
TR Transformer
PA Air pressure switch
GRY-I 15 WU / 25WU / 40WU
GRY-D 60WU
blue
brown
L
N
TR
black
black
FS
white
white
black
M
black
EARTH
TR
SV
PHOTO
PHOTO
MT
INT 1
black
black
IN
INT 2
P
PA
FC
black
N
N
L
N
N
black
EV
Optional
2
3
1
TH
green
green
brown
TR Transformer
FS
TH
IN
M
EV
FC
Air solenoid valve
Remote thermostat (optional)
Fuse
Switch
Motor
Photocell
PA Air pressure switch

Other manuals for Munters GRY-D 40 WU