Operator’s Manual
GB
Direct-fired
Diesel/Kerosene Air Heaters
JAZ 42
JAZ 80
JAZ 80 W
JAZ 125
JAZ 160
IMPORTANT: Read and understand this manual before
assembling, starting or servicing the heater. Improper use
of this heater can cause serious injury. Keep this manual
for future reference.
JAZ

Questions and Answers

  • T
    Terry MullinsAug 16, 2025
    Why Munters Heater motor will not start?
    • P
      paul68Aug 16, 2025
      If the motor of your Munters Heater won't start and the green indicator light is quickly flashing, it could be due to no power or low voltage, a blown fuse, a thermostat set too low, or a faulty power cord, extension cord, motor, or capacitor. Check the power supply and voltage. Try resetting the heater by turning the On/Off switch to O and then to I. Replace the fuse if it's blown. Turn the thermostat knob clockwise to a higher setting. Inspect and replace the power cord, extension cord, motor, or capacitor if needed.
  • K
    kelseysilvaAug 22, 2025
    What to do if Munters JAZ 42 motor runs but fuel does not ignite?
    • D
      delgadojohnAug 23, 2025
      If the motor of your Munters Heater runs, but the fuel does not ignite and the heater shuts off after 5 seconds, it could be due to a low or empty fuel tank, dirty or wrong fuel, a clogged fuel filter, leaks in fuel or air hoses, a faulty ignition transformer or control board, a dirty or fouled spark plug, or a clogged fuel nozzle. Fill the tank with fresh kerosene fuel. If the fuel is dirty, remove it and replace it with clean kerosene fuel. Clean or replace the fuel filter. Check the hoses and replace them with original parts if necessary. Consider replacing the ignition transformer or control board. Check, clean, or replace the spark electrode. Clean the nozzle by blowing compressed air through the front; replace it if necessary.
  • A
    Antonio HernandezAug 28, 2025
    How to fix faulty photocell in Munters JAZ 42?
    • J
      Joseph KellyAug 29, 2025
      Clean or replace the photocell sensor in your Munters Heater.
  • M
    Michael SmithSep 3, 2025
    How to fix faulty control board in Munters JAZ 42 Heater?
    • A
      Allison HardingSep 3, 2025
      Replace the control board of your Munters Heater.
  • M
    Marcus MooreNov 10, 2025
    What to do if Munters Heater stops during operation?
    • S
      Scott WhiteNov 10, 2025
      If your Munters Heater stops during operation, it could be due to several reasons. It might be that the desired room temperature has been reached, and the heater is in STAND-BY MODE, which is normal. To restart, simply turn the thermostat knob clockwise to a higher setting. Other potential causes include a loss of power supply, a blown fuse (in which case, replace the fuse after turning the On/Off switch to O and then to I), or an incorrect fuel/air mixture. If the fuel/air mixture is too rich (too much fuel or not enough air) or too lean (too much air or not enough fuel), ensure a correct mixture, check for blockage of the air inlet, a dirty or damaged fan, or bad fuel; remove obstructions, and clean parts, using the correct fuel or clean kerosene and ensuring correct compressor pressure....

Munters JAZ 42 Specifications

General IconGeneral
Heat output42 kW
Frequency50/60 Hz
Phase1
Protection ClassIP44
TypeDirect-fired gas heater
Gas typePropane