EasyManua.ls Logo

Munters JAZ 42 - Abnormal Operation; Maintenance

Munters JAZ 42
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
1. Thermostat Control Knob
2. Green Indicator Light
3. On/Off Switch
4. Fuseholder
5. Power Cord Socket
To Start the Heater
1. Turn the ON/OFF switch (3) to the ON (“I”)
position. The green indicator light above the
On/Off switch will flash slowly (every 3 seconds),
indicating STAND-BY MODE.
2. Turn the thermostat knob slowly clockwise
until the heater starts. The green indicator light
above the On/Off switch will remain lit
continuously, ON MODE.
3. Adjust the thermostat to the desired
temperature [setting/position?]. One or two
adjustments may be required to obtain the
desired temperature.When the thermostat
senses the temperature has been reached, the
heater will cycle off and return to STAND-BY
MODE. The thermostat will cause the heater to
automatically turn on and off to maintain the set
temperature.
Note: Air temperature and wind velocity around
the heater may affect the thermostat operation.
Adjustments to the thermostat setting may be
required to obtain the desired comfort level.
This heater is equipped with a
thermostat. When in the STAND-BY MODE,
the heater may start at anytime on thermostat
command. Keep children and animals away
from heater area at all times!
Maintain adequate clearances
from combustible materials at all times
during operation. See "Minimum Safety
Clearances from Materials and Objects in the
Surroundings of the Heater" in the Electrical
Connection and Installation section, above.
Do not start the heater if the
combustion chamber is hot or if excess fuel
has accumulated in or around the
combustion chamber. Accumulated fuel
could result from repeated unsuccessful
ignition attempts. Unplug heater and remove
excess accumulated fuel before attempting
restart.
Never leave the heater
unattended while burning or connected to a
power source.
4. To operate the heater in “CONTINUOUS ON”
MODE, turn the thermostat knob fully clockwise.
IMPORTANT: If the heater fails to start the
indicator light will FLASH rapidly (four times per
second) indicating LOCK-OUT MODE.
If the heater goes into lock-out mode, check and
remove the cause of lock-out before restarting
the heater. See Troubleshooting, page… To
reset, turn the ON/OFF switch to 0 and then
again to I. If repeated LOCK-OUT occurs, call
Customer Service (+1-239-936-1555).
NOTE 1: turning the thermostat knob will NOT
reset the heater.
NOTE 2: in case of power failure and restoration
5. ABNORMAL OPERATION: in case of
malfunction (flame failure, reduced air flow, bad
combustion, etc.) the heater stops and the
indicator light starts FLASHING QUICKLY
(LOCK-OUT MODE).
6. POWER FAILURE: in case of power supply
failure, the green indicator light will not be lit and
the heater must be manually reset. Turn the
On/Off switch to Off ("O") and then to the On ("I")
position to restart the heater as power supply is
restored.
To Stop the Heater
1. Turn the On/Off switch to OFF (“O”) position.
2. Unplug the heater.
7. Cleaning, Maintenance and
Storage
Regularly wipe the enclosure using a soft sponge
or cloth. For very dirty parts, use a sponge
Fig. 7