2.7
Switch the current operating mode
When unit is ON. Under the main interface long press the key can switch the current running mode.
Tank temp.
Ambient temp.
Inlet water temp.
Ambient temp.
C C C C
M
Hot water mode
Inlet water temp.
Ambient temp.
M
Heating mode
Inlet water temp.
Ambient temp.
Attention: hot water mode, hot
water and cooling mode, hot
water and heating mode are not
available for pool heat pump
C C C C
M
Cooling mode
M
AUTO mode
Tank temp.
Inlet water temp.
Tank temp.
Inlet water temp.
C C C C
M
Hot water and cooling mode
M
Hot water and heating mode
2.8 Open/close energy saving mode
Press the
and
for 3 seconds at the same time to enter the energy saving mode. Open the energy saving, the light up of on
the
main interface means you have enter the energy saving mode. Each mode has its unique energy saving plan specified as below:
Cooling mode of energy saving scheme
When the ambient temperature is 32 ℃or higher, set the water temperature to 8 ℃.
When the ambient temperature is 27 ℃~ 30 ℃, set the water temperature to 10 ℃.
When the ambient temperature is 25 ℃or lower, set the water temperature to 12 ℃.
Heating mode of energy saving scheme.
There are two kinds of energy-saving solution for this mode, it is determined by the user parameter L6 setting.
When parameter L6 is selected to be 0, it’s curve heating energy saving solutions; when the parameters of L6 is
selected to be 1, it is the adjust water temperature according to the setting period.
Set the water temp./℃
55
Curve heating energy saving scheme
This scheme is designed to adjust the inlet water temperature
according to the ambient temperature and the setting curve.
45
When leaving the factory, the curve has been set as shown in this
40
figure (slope 40,
translation of 10). Users can check the current inlet
water temperature according to this figure
30
If user needs to adjust the curve, an appendix is available for
reference.
25
20
15
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Ambient temp./℃
(Pay attention to the factory Settings for: maximum set temperature limit is 55 ℃, the curve slope is 30,
curvilinear translation amount of 10)