3.2.4 AC voltage
Range
Resolution
Accuracy
±( 0.8% reading + 5 digits)
600V 0.1V
-
Min. input voltage: 0.5 V AC
- Max. input voltage: 600V AC (valid value)
- Frequency range: 45 ~ 1000Hz
3.2.5
Range Resolution Accuracy
±( 0.8% reading + 5 digits)
- Min. input voltage: 0.1 mV AC
- Max. input voltage: 600V AC (valid value)
AC voltage
AC voltage
Line on-off test
Range
Resolution
Function
1Ω
Ω
- Overload protection: 250V DC or AC (valid value)
If the measured line
resistance is less than 50 ,
the buzzer in the meter will
sound
3.2.6 Resistance
Range
Resolution
Accuracy
600Ω 0.1Ω
± (0.8% reading + 3 digits)
6kΩ 0.001kΩ
60kΩ
0.01kΩ
600kΩ 0.1kΩ
6MΩ
0.001MΩ
60MΩ 0.01MΩ
7