MAINTENANCE AND CLEANING
Before cleaning disconnect the unit from the mains power supply. And make
sure the plate is completely cold. Do not use alcohol or abrasive products and
not allow the appliance to contact volatile agents such as gasoline, solvents,
insecticides, etc.
Cleaning the cooking plate
After each use you should clean the plate, thus it will prevent burning
remains attached.
Do not clean the plate until it is cold enough.
Use only specific products for cleaning induction plates, failure to do so
could damage the cooking surface.
Never use scouring pads that may scratch the surface, nor should use
abrasive cleaning fluids how sprays for furnaces.
Cleaning the plastic surface
Clean the plastic surface with a damp cloth and then with a dry one. Avoid
water from the vents.
If you see the holes in the fan has accumulated a lot of dirt, remove it with
a brush.
PROBLEM SOLVING
If there is any abnormality or problem in the operation of the induction hotplate,
the display 4 or 13 show the detected error of the corresponding cooking zone.
Error messages appear on the screen with the letter " E " followed by a number,
see the table below to identify the error and solution.
Message Description Solution
E0
No container, the container is not
suitable for induction or the diameter
of its base is less than 12 cm
Place a container on the cooking zone or
replace the container that is invalid.
E2
The NTC sensor is defective
Contact our Customer Service nearest MX
ONDA.
E3, E4
Undervoltage protection
or overvoltage portection
If the voltage at the outlet network is less
than or greater than that specified, consult
a qualified electrician.
E5
The glass or ceramic plate has
overheated
Unplug the induction plate and allow to
cool.
E6
It is activated overheating protection
Failure in the ventilation system, check that
the fan is not clogged and functioning
properly. Unplug the induction plate and
allow to cool.