Operation
Manual
MODELS 6P & 4P
ULTRAMETER

Table of Contents

Questions and Answers

  • R
    Robert HerringAug 4, 2025
    Why are my Conductivity/TDS/Resistivity readings unstable on Myron L Analytical Instruments?
    • A
      Andrew McintoshAug 4, 2025
      Unstable readings in Conductivity, TDS, or Resistivity measurements with Myron L Analytical Instruments can often be traced to dirty electrodes. Cleaning the electrodes can resolve this. Also, ensure that the test samples have appropriate conductivity, especially if they are greater than 1 megohm.
  • J
    Jeffery RayAug 8, 2025
    What to do if Myron L Analytical Instruments have no display even when the measurement key is pressed?
    • J
      Jennifer GarciaAug 9, 2025
      If your Myron L 6P Analytical Instrument shows no display when you press the measurement key, the battery may be weak or not properly connected. Check the battery connections and replace the battery if necessary.
  • M
    Matthew WaltonAug 12, 2025
    Why are the pH readings inaccurate on my Myron L 6P Analytical Instruments?
    • M
      Maria WilliamsAug 13, 2025
      Inaccurate pH readings on your Myron L 6P Analytical Instruments can stem from several causes. It could be due to the need for pH calibration. Another potential cause is cross-contamination from residual pH buffers or samples in the sensor well, so ensure you clean the sensor well thoroughly. Also, using fresh pH buffers for calibration is important, as expired buffers can lead to inaccuracies.
  • K
    Kimberly GayAug 17, 2025
    What to do if Myron L 6P Analytical Instruments show no response to pH changes?
    • A
      Amy AndersonAug 17, 2025
      If your Myron L 6P Analytical Instruments show no response to pH changes, the sensor bulb might be cracked, or there could be an electromechanical short due to an internal crack. Inspect the sensor for damage and replace it if necessary.
  • R
    Robert BerryAug 21, 2025
    Why are resistivity readings much lower than expected on Myron L Analytical Instruments?
    • B
      brian32Aug 21, 2025
      If the resistivity readings on your Myron L Analytical Instruments are much lower than expected, it could be due to contamination from a previous sample or from the pH sensor well. Cleaning the pH sensor well and electrodes may help. Also, carbon dioxide in the test sample can cause this issue, so ensure your sample is free from carbon dioxide.
  • R
    Robert AyersAug 26, 2025
    What to do if Myron L 6P Analytical Instruments will not adjust down to pH 7?
    • P
      Paul TaylorAug 26, 2025
      If your Myron L 6P Analytical Instruments will not adjust down to pH 7, it's possible that the pH/ORP sensor has lost KCl. Replenishing the KCl in the pH/ORP sensor should resolve this issue.
  • R
    Richard SmithAug 30, 2025
    Why do pH readings drift on Myron L 6P Analytical Instruments?
    • H
      Hailey MayAug 30, 2025
      Drifting pH readings or slow response to changes in buffers/samples, or repeated display of “FAC” on your Myron L 6P Analytical Instruments, can be caused by several factors. It may be a temporary condition due to the sensor's “memory” of a solution in the pH sensor well for extended periods; in this case, allow the sensor to stabilize. Alternatively, the bulb might be dirty or dried out, so clean the pH sensor bulb. A clogged or coated reference junction can also cause these issues; clear any blockage in the reference junction.

Summary

I. Introduction

II. Features and Specifications

Features

Lists the key functional attributes of the Ultrameter II.

General Specifications

Details physical dimensions, materials, power, and operating conditions.

Specification Chart

Presents detailed technical specifications in a tabular format.

Warranty;Service

Outlines the warranty period and service procedures for the instrument.

III. Rules of Operation

Operation

Provides a basic guide on how to use the instrument for measurements.

Measurement Keys Overview

Details the specific functions of each measurement key.

COND, RES, and TDS Keys

Explains the operation of keys for conductivity, resistivity, and TDS measurements.

pH and ORP Keys (6 P)

Details the operation of keys for pH and ORP measurements on the 6P model.

V. Specific Recommended Measuring Procedures

Measuring Conductivity & TDS

Step-by-step guide for measuring conductivity and total dissolved solids.

VI. Solution Selection

Application of USER Solution Type

Details how to use the USER mode for custom temperature compensation and TDS ratios.

VII. Calibration

Rules for Calibration

Outlines the general rules and steps for calibrating the instrument.

Calibration Procedures

Details the specific steps for calibrating conductivity, TDS, resistivity, pH, and ORP.

pH Calibration (6 P)

Step-by-step guide for calibrating the pH function on the 6P model.

ORP Calibration (6 P)

Explains the electronic calibration process for the ORP function.

IX. Memory

XII. Total Return to Factory Settings FAC SEL”

XIII. Cell Check

XV. User Mode Calibration Linc Function

Setting User Mode Calibration Link

How to link a standard solution's calibration to the User mode.

XVIII. Troubleshooting Chart

XX. Temperature Compensation (Tempco) of Aqueous Solutions

XXIII. pH and ORP (6 P)

Myron L ULTRAMETER II 4P Specifications

General IconGeneral
Measurement ParameterspH, ORP, Conductivity, Resistivity, TDS, Salinity, Temperature
pH Range0.00 to 14.00 pH
pH Accuracy±0.01 pH
ORP Accuracy±1 mV
Conductivity Accuracy±1% of reading
Resistivity Accuracy±1% of reading
TDS Accuracy±1% of reading
Salinity Accuracy±1% of reading
Temperature Accuracy±0.5 °C
DisplayLCD with backlight
Conductivity Range0 to 200 mS/cm
Resistivity Range0.00 to 100.0 MΩ·cm
Resolution0.01 pH, 1 mV, 0.01 mS/cm, 0.01 MΩ·cm, 1 ppm, 0.01 ppt, 0.1 °C
Temperature CompensationAutomatic
Power Supply9V battery
Operating Conditions0 to 50 °C, 0 to 95% RH
Storage Conditions0 to 95% RH