TROUBLESHOOTING
SYMPTOM: Unit will not turn on.
PROBLEM: Not plugged in.
SOLUTION: Plug machine in proper outlet.
PROBLEM: Circuit breaker has popped.
SOLUTION: Reset circuit breaker. Make sure no other items are running on
the same circuit as machine. Outlet must be a 20-amp circuit.
PROBLEM: Wire from power cord has become disconnected from terminal
block.
SOLUTION: Reattach wire to terminal block.
SYMPTOM: Pump is not running properly.
PROBLEM: Quick disconnects are not completely locked together.
SOLUTION: Snap quick disconnects firmly together.
PROBLEM: Switch on switch plate is bad.
SOLUTION: Replace switch.
PROBLEM: Jet on upholstery tool is clogged.
SOLUTION: Clean jet with soft wire brush or remove jet and flush clean.
PROBLEM: Filters are clogged.
SOLUTION: Remove filters and rinse with clean water.
PROBLEM: The solution tank is empty.
SOLUTION: Fill the solution tank up with a premixed detergent.
PROBLEM: Pump wire has become disconnected.
SOLUTION: Reconnect wire.
PROBLEM: Heater is blocked with hard water deposits.
8