3.13User defined error
Item Description
Failure code
This is the error number. (7001 to 7200)
INFO.
If the system software version is less than FDV03.21,
the setting range is from 7001 to 7099.
Input
Signal
This
is
the
trigger
signal
(input
signal)
to
display
the
error.
(0
to
2048)
Failure Type
Select the type of the
error (Error / Alarm / Information)
For details, refer to the
following manual.
CONTROL AND MAINTENANCE FUNCTION Chapter 4
In case of Information, Error reset or Signal off
can be selected.
This setting can be changed only i
n case of Information.
INFO.
This setting item is available only in the system
software FDV03.21 or
after.
Error reset
The information display can be turned OFF in case of
error rest, motors ON, program start, or teach
pendant operation, etc.
The information display is not turned OFF when input
signals are turned OFF.
Clear info. disp.
Signal off
The error reset, motors ON, program start, or teach
pendant operation cannot turn OFF the information
display.
When the input signal turns OFF, the display of the
information will turn OFF.
Failure message
Input the error message
Character input screen is displayed by [Enable] +
[Edit].
Failure content
Input the error content.
Character input screen is displayed by [Enable] +
[Edit].
Measures
Input the measures.
Character input screen is displayed by [Enable] +
[Edit].