4.2 Registering Start Enable Area
4.2
Registering
Start
Enable
Area
This function enables to register the safe position to start the robot (Start enable area), which restricts the start if
the robot is not within the specified area. The difference from the home position registration system is that robot
controller itself can confine the robot start.
IMPORTANT
To restrict the robot start by robot controller using the Start enable area, the setting for
Start enable area shall be specified as the condition of Unit READY in the section
4.3.2
Unit READY signal
.
The start enable area can be registered to the mechanism one to one. When all the mechanisms included in a
unit are in the registered area, the unit is considered within the range of start enable area. For the management
unit, all the
mechanisms in a system are to be checked.
4.2.1
Registering the start enable area
Note that the operator qualification of
EXPERT
or higher is required for this operation.
1
Select the teach mode.
2
Select <Constant Setting> - [9 Area] [3
Possible Field to start].
>>The following screen appears.
3
Align the cursor with Area Definition and press [Enable] + [Right/Left] key at a
time to move the
radio button to defined.
4
Move to the axis to
set the area, and
press [Enter] key.
>>Now
, you can
input the
value. T
o restore the
screen, press [Enter] key again.
5
When the value input is
available, enter the area to
set and press [Enter] key.
>>The input is now fixed. No more value input is available.