On the Home Interface, press and hold both and buttons for
over 10S, during the process, the icon will flash slowly, the
Display Auto OFF function can be enabled or disabled, when the
function is enabled, the icon will be displayed, otherwise the
icon will not be displayed.
This Display Auto Off can also be configured through the propri-
etary attribute 0x100B of Thermostat Cluster (0x0201).
On the Home Interface, press and hold both and buttons for
over 10S, the Child Lock can be enabled or disabled, when the
Child Lock is enabled, the icon will appear at the upper right
corner, otherwise the icon will not appear.
This Child Lock can also be configured through the attribute
KeypadLockout (0x0001) of Thermostat Cluster (0x0201).
Select OTHER SET on Home Interface to enter into OTHER SET
interface as follow:
Short press button to select the item you would like to modify,
then short press move up and down buttons to modify value of
selected item, then short press button to save and quit, short
pressing button only quits without saving.
The displayed temperature may has big tolerance caused by the
sensor or other factors, so it is necessary to do
temp compensation to room sensor and floor sensor.
Compensation range is -5 ~ +5°C, stepping is 0.5°C.
This value can also be configured through the attribute Local
TemperatureCalibration (0x0010) of Thermostat Cluster (0x0201),
and through the proprietary attribute FloorSensorCalibration
(0x1005) of Thermostat Cluster (0x0201).
Other Set
Temperature
Compensation 0 by default
last status by
default
Home Temp by
default
Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure
after power on again.
If set as “default”, device will go to default mode after power on
again.
This status can also be configured through the proprietary attribute
PowerUpStatus (0x1004) of Thermostat Cluster (0x0201).
Re-power
Status
To ensure the safety of the device, if the internal temperature of the
device (not displayed on the interface) is over a certain value during
heating process, the device will execute a short temporary action to
turn off the relay, and the icon will appear on the interface, after
the temperature decreases to a certain value, the device will recover
to work.
Internal Over
Heat Protection
F
Child Lock
This parameter defines which sensor temperature will be displayed
on Home page.
Floor Temp: floor temperature (external sensor) .
Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute
TemperatureDisplay (0x1008) of Thermostat Cluster (0x0201).
Display
Temperature Set
Display
Auto Off
F
F