Cleaning and Maintenance
CAUTION! Keep the stainless steel probe sensors and cords away from children. Use care when
handling the probes. Always wear a heat resistant glove to touch the stainless steel probe sensors or
cords during and right aer cooking. Do not use probe cables or rings to move probes.
CAUTION! Do not use the probes in microwave ovens or on a rosserie.
Clean the probes before using for the rst me.
Hand wash the metal poron of probes and dry thoroughly aer each use. Do not wash in a
dishwasher.
NOTE: The probe jacks, probe cables and display unit are water resistant but should not be le in the rain.
The appliance should never be immersed in water.
Probes are rust-proof and corrosion resistant. Do not use any chemicals or cleaning soluons to
clean the probes except mild soap.
Use the cord wraps for tangle-free cord storage and to prevent kinks and folds.
Store Bluetooth thermometer in ambient temperatures ranging from 32 ⁰F to 95 ⁰F / 0 ⁰C to 35 ⁰C
Only use alkaline or carbon zinc baeries.
Remove baeries when storing for long periods of me.
Napoleon ACCU-PROBE™
Bluetooth® Thermometer
Safeguards
Probes can operate within -4⁰F to 572⁰F / -20⁰C to 300⁰C
Probe cords can operate within -4⁰F to 716⁰F / -20⁰C to 380⁰C
! Do not allow the probes to be directly exposed to ames or temperatures exceeding 572⁰F / 300⁰C.
For accurate readings, insert the probes into the center of meat ideally before it is placed on the grill.
! Point the ps downward, but do not allow the ps of probes to touch the grill grates. Also try to
ensure that probes do not touch the grill.
Place meat on the side of the grill closest to the thermometer.
Posion the cord at a high exit point so the cord stays suciently above the grill when the lid is closed.
Alternavely, probe handles may be posioned under the lid seal. Ensure the sides of the grill do not
exceed the highest operang temperature.
When using more than one probe, colored probe rings can help idenfy the number of each probe.
Place each around the probe p and push ll it reaches the base holder.
Check Clearance Prior to Cooking
Check that the cooking area does not exceed the maximum temperature and cords are not kinked or
frayed by closed doors or lids.
First check the cord clearance at ambient temperature with the cooking unit closed; examine the cord for
any severe kinking or bending.
Then turn the temperature unit on and use the probe to examine hot spots where the cord may make any
surface contact.

Other manuals for Napoleon ACCU-PROBE 70077

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon ACCU-PROBE 70077 and is the answer not in the manual?

Napoleon ACCU-PROBE 70077 Specifications

General IconGeneral
BrandNapoleon
ModelACCU-PROBE 70077
CategoryThermometer
LanguageEnglish