3.
Error Messages:
Any error preventing normal operation will be displayed on the screen . In that
case, any running
cooking or cooking program will be cancelled. The message will remain
on the screen until
is pressed ,
even if the error has been recovered.
Error Code
Explanation
Error 1
Temperature Sensor Error
The connector of the sensor may be loose or disconnected.
Temperature sensor malfunction .
Power Module malfunction
Error 2
User Module Temperature limit exceeded
The ambient Temperature of the user module is > 85C.
Cooling Fan malfunction .
User module malfunction
Error 3
User Module Temperature Limit Sensor Error
User module malfunction
Error 4
Meat Probe short circuit error
Meat probe malfunction.
Power Module malfunction
Error 5
10 hours cooking duration limit as manual or meat probe cooking is exceeded..
Error 6
Real Time Clock Error
The real time clock IC on the user module is defect.
Error 7
WiFi module ( optional ) error
WiFi module malfuction.
WiFi module connector loose or disconnected .
Error 8
Power Section Error ( oven gets not heated or does not cool down )
Loose heating element connection
Power Module malfunction
Error 9
Frequency Error
The crystal oscilator of the real time clock is defect.