EasyManua.ls Logo

Nautyl PHCP50 - Technical Parameters

Nautyl PHCP50
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
III. Technical Parameters
Model
PHCP50 PHCP65 PHCP80 PHCP110
Voltage 208-230V/60Hz
Frequency/phase 60Hz/1Ph
Heating current (air80°F,water80°F) 10.8A
11.8A 15.6 A
21.3 A
Heating power (air80°F,water80°F) 2.3KW 2.6KW 3.4 KW 4.4 KW
Heating current (air80°F,water95°F) 13.2 A 13.3A 19 A 24.5 A
Heating power (air80°F,water95°F) 2.7 KW 2.9KW 3.9 KW 5.7 KW
Compressor RLA/LRA 11.6A/60.2A 12.9A/66.9A 21.2A/123A 30.2A/139A
Fan motor rating 0.5 A 1.1A 1.2 A 1.2 A
Design pressure (High)
609 PSIG 609 PSIG 609 PSIG 609 PSIG
Design pressure (Low)
261 PSIG 261 PSIG 261 PSIG 261 PSIG
Refrigerant (R410A) 56.4oz 74.1oz 95.2oz 116.4oz
Net weight (KG) 68 78 112 135
Water circulation flow 83-116 L/min 108-142L/min 108-142 L/min 133-167 L/min
Noise
50 dB(A) 58 dB(A) 50 dB(A) 58dB(A)
Waterproof class IPX4 IPX4 IPX4 IPX4
Remarks:
1. This product can work well during air temp 32℉~109 (0ºC to 43°C). Efficiency will not be
guaranteed out of this range and parameters are different under various conditions.
2. Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.