Wood pellets are jamming the rotary valve in the vacuum unit.
1. Turn down the Durtycycle % under Menu TRANSPORT. This will prevent the rotary valve from over filling.
2. Make sure that your wood pellets are no longer than 35mm.
There is not enough suction.
1. Check that all the connections are tight.
2. Check the filter for any build up of dust.
3. Check that the running time is not too long; which can over fill the cyclone with pellets.
4. Check that the vertical lift height is no taller than 3.5 meters.
5. Check that the transport distance is no more than 15 meters.
6. Check that all pipes are of the same dimension.
There is no power to the system.
1. Make sure that there is power on the contact.
2. Check to see if the fuse ( 7A ) is functional. Replace if neccessary.
The extraction auger cannot empty the silo.
1. Check that the sides of the silo are greater than 45 degrees.
2. Make sure that there is no more than 1% dust in the pellets.