caution
the D curve is specific for euro 6 engines with smart
alternators and entails a delay of several seconds for the
activation of the system, wait until the end of the
procedure.
Model
12V
24V
max voltage
14,5V
29V
float voltage
13,5V
27V
max desulfation voltage
not allowed
C curve: generic curve (flooded, LiFePO
4
)
d curve: generic curve for smart alternator,
euro 6 (LiFePO
4
)
Model
12V
24V
max voltage
14,6V
29,2v
float voltage
13,7V
27,4V
max desulfation voltage
not allowed
no
yes
no