6. charging curves
powerservice units support battery charging for AGM, Gel and
flooded lead-acid batteries or Vmax 14.5V, a special curve for
Euro 6 systems with “smart” alternators and LiFePO4 lithium
batteries . The charge curves are selectable using two jumpers.
11
yes
no
Model
12V
24V
max voltage
14,8V
29,6V
float voltage
13,8V
27,6V
max desulfation voltage
15,8V
31,6V
yes
yes
Model
12V
24V
max voltage
14,3V
28,6V
float voltage
13,6V
27,2V
max desulfation voltage
15,8V
31,6V
a curve: AGM
b curve: gel