    Jacob PittmanAug 21, 2025
    What to do if all LEDs flash 5 times on NDS POWERSERVICE PLUS 25?
    • K
      Kayla GonzalezAug 21, 2025
      If all the LEDs on your NDS Battery Charger flash 5 times accompanied by a buzzer, here's what might be happening and how to address it: * **Fuse Failure:** Check the integrity of the 2 x 25A fuses at the "out" pin. * **High Solar Panel Voltage:** Ensure the solar panel voltage (pin 7) is less than 28V. * **Electronic Board Overheating:** Allow the system to cool down. * **Restart the device:** Restart the device at full speed (with the battery not fully charged).
  • C
    Calvin CooperAug 31, 2025
    Why are alternator and solar panel LEDs continuously on NDS POWERSERVICE PLUS 25?
    • M
      Molly MooreAug 31, 2025
      If the alternator and solar panel LEDs are continuously on with your NDS Battery Charger, it indicates that the external temperature detected is below -2°C. This is a security system feature when charging curve 3 or 4 is selected. The LED will turn off once the temperature rises above 0°C.
  • M
    Matthew ReynoldsNov 10, 2025
    Why is the alternator LED flashing 6 times on my NDS POWERSERVICE PLUS 25 Battery Charger?
    • R
      Richard HuertaNov 10, 2025
      If the alternator LED flashes 6 times on your NDS Battery Charger, it could be due to several reasons: * A voltage drop on the alternator: Ensure the cables have a minimum section of 10mm2. * Insufficient alternator power: Verify the connections on terminals 1, 2, 3, and 6. * Overheating power components: The system automatically reduces the charging current until the alarm stops. * Power loss on the cables: Connect the cable attached to terminal 1 directly to the negative pole of the engine battery (or services), cable attached to terminal 2 directly to the negative pole of the service battery (or motor), the cable relative to terminal 3 to the positive pole of the engine battery, or positive pole of the alternator, and the cable relative to terminal 6 to the positive pole of th...