00H : OFF
01H : ON
FFH : Not Supported
DATA33 Test pattern display 1
00H : No display (Normal condition)
00H Other : Displaying (Pattern ID)
Pattern ID Pattern Name MT LT LT180 LT80 HT GT W T VT NP1000 NP3150 NP905 NP4000 NP4100 NP62 NP64 NP3250 NP216 P420 V300
02HCross Hatch-**-*----*** **** ***
03H Gray Bars ** * * **** * * * - - - - * - * -
04H Raster(0%) ** * * **** * * * * * * * * * * *
05H Raster(25%) ** * * **** * * * * * - - * * * *
06H Raster(50%) ** * * **** * * * * * - - * * * *
07H Raster(100%) * * * * * * * * * * * * * * * * * * *
08H Focus ** * * **** * - - - - - - - - - -
09HRaster Blue*--*-*-***** **** ***
0AH Gray Raster 30 * * * * * * * * * * * * * * * * * * *
17H Gray Raster 10 * * * * * * * * * * * * * * * * * * *
18HRAMP WBRG-**-*-*-- --- -**- *-*
19HBlue Raster 60-**-*-*-- --* ***- ***
1DH Cross Hatch 3 * *1 * * - * * * * - - - - - - - - - -
* : Supported
- : Not supported
*1: Only LT240K/260K
DATA34 Test pattern display 2
FFH: No display (Normal condition)
FFH Other: Displaying
Bit 2: BLUE pattern
0 = OFF
1 = ON
Bit 1: GREEN pattern
0 = OFF
1 = ON
Bit 0: RED pattern
0 = OFF
1 = ON
DATA35 .. 50 Reserved
DATA51 .. 65 User registration name ( 14 characters + NULL )
DATA66 Forced On-screen mute
00H : OFF
01H : ON
DATA67 On-screen display
00H : No display
01H : Displaying
DATA68 Selecting signal processing
00H : No execution (Normal condition)
01H : During execution
DATA69 Status of operation
00H : Idling
04H : Power On
05H : Cooling
06H : Idling (Error occurrence)
Other than above: (nondisclosure)
Internal use of code during a state transition period
DATA70 .. 71 Projector type