009. ERROR STATUS REQUEST
**********************************************************************
Function:
This command acquires the error information occurring with the projector.
Command:
00H 88H 00H 00H 00H 88H
Response: At the time of a success
20H 88H 01H xxH 0CH DATA01 .. DATA12 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
* The various bits are normal is "0" and error is "1".
* "None" is "0" fixation.
DATA01 Error Status (1)
bit0 : Lamp cover error
bit1 : Temperature error(Bimetal)
bit2 : None
bit3 : None
bit4 : Fan error
bit5 : Power error
bit6 : Lamp(or Lamp1) error
bit7 : Lamp(or Lamp1) has reached its end of life
DATA02 Error Status (2)
bit0 : Lamp(or Lamp1) has been used beyond its limit
bit1 : Formatter error
bit2 : Lamp2 error
bit3 : None
bit4 : None
bit5 : None
bit6 : None
bit7 : None
DATA03 Error Status (3)
bit0 : None
bit1 : FPGA error
bit2 : Temperature error(Sensor)
bit3 : Lamp(or Lamp1) housing error (!)
bit4 : Lamp(or Lamp1) data error (!)
bit5 : Mirror cover error
bit6 : Lamp2 has reached its end of life
bit7 : Lamp2 has been used beyond its limit
DATA03 Error Status (4)
bit0 : Lamp2 housing error
bit1 : Lamp2 data error
bit2 : High temperature due to dust pile-up
bit3 : A foreign object sensor error
bit4 : Pump error
bit5 : None
bit6 : None
bit7 : None
DATA05 .. 12 Reserved
Response: At the time of a failure
A0H 88H 01H xxH 02H DATA01 DATA02 CKS