Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has
been manufacturing transfer switches and equipment in Racine, Wisconsin since 1982 and has been producing
high-quality electrical equipment for nearly 100 years. Reliance is the Loadsidtransfer switch used in nearly
90% of the installations done by professional electricians. Your transfer switch is UL 1008 listed, for the U.S. and
Canada
, and meets all requirements of the National Electrical Code.
STANDBY POWER FURNACE SWITCH
Easy/Tran
®
TF151, TF151W, TF201 and TF201W
TOOLS NEEDED FOR INSTALLATION
1. Power Drill 6. Tape Measure
2. Wire Stripper and Cutter (10 to 14 gauge) 7. Three Wall Anchors
3. Insulated Screwdrivers 8. Battery Powered Lighting during Installation
(#2 Phillips, ¼” Flat Tip or #2 Square Tip 9. A Non-Contact Voltage Detector (optional)
depending on your load center)
4. Hammer
5. Marking Pencil
PARTS LIST for Easy / Tran
TF
FURNACE TRANSFER SWITCH
15 Amp (TF151) or 20 Amp (TF201) Single-Circuit Transfer Switch
4 Yellow Wire Connectors
SAFETY SYMBOLS USED IN THIS MANUAL
Danger indicates an imminently hazardous
situation that, if not avoided, could result in
death or serious injury.
Warning indicates a potentially hazardous
situation that, if not avoided, could result in
death or serious injury.
Caution indicates a potentially hazardous
situation that, if not avoided, may result in
minor or moderate injury.
Improper installation of the transfer
switch could cause damage or personal injury by
electrocution or fire. Installation must be performed
by a qualified electrician, or others knowledgeable of
electrical systems, in compliance with all applicable
electrical codes.
Reliance transfer switches covered in
this manual should not be used for electric water
heaters, clothes dryers, electric ranges, central air
conditioners or other appliances or systems that may
exceed the capacity of the product.
Transfer swit
ches are required for use with portable
generators by Article 702 of the National Electrical Code
Reliance Controls Corporation is
not responsible for damage or
injury caused by incorrect
installation of this transfer switch.
Member of the National Electrical Manufacturers Association
Question and Answer IconNeed help?

Do you have a question about the NEMA Reliance Controls Easy/Tran TF151 and is the answer not in the manual?

NEMA Reliance Controls Easy/Tran TF151 Specifications

General IconGeneral
TypeTransfer Switch
Amperage15A
Voltage120V
NEMA RatingNEMA 3R
Number of Circuits6
Poles2
OperationManual
CertificationUL Listed

Summary

Tools Needed for Installation

Parts List for Easy/Tran TF Furnace Transfer Switch

Safety Symbols and Warnings

Danger

Indicates an imminently hazardous situation that could result in death or serious injury.

Warning

Indicates a potentially hazardous situation that could result in death or serious injury.

Caution

Indicates a potentially hazardous situation that could result in minor or moderate injury.

General Safety and Installation Warnings

Highlights risks of incorrect installation, electrocution, fire, and improper use.

Key Components of the Furnace Transfer Switch

Branch-Rated Circuit Breaker

Describes the circuit breaker function and protection for the branch circuit.

Panel Light

Explains the function of the panel indicator light powered by the generator.

Toggle Switch

Details the operation of the GEN/LINE/OFF toggle switch for power source selection.

Pre-Wired Flexible Conduit Whip

Describes the conduit whip for connecting the switch to the load center.

Installation Instructions

Mounting the Easy/Tran

Instructions for physically attaching the transfer switch to a surface.

Connecting Models TF151 and TF201

Wiring instructions for specific furnace-mounted models.

Connecting Models TF151W and TF201W

Wiring instructions for load center-connected models.

Connecting the Neutral and Ground Wire

Procedure for connecting neutral and ground wires to the load center.

Connecting a 120 Volt Furnace Circuit

Procedure for connecting the furnace circuit wires to the transfer switch.

Finishing Up Installation

Final steps including turning on breakers and setting the toggle switch.

Operating Instructions

Monthly Generator Readiness Check

Steps to ensure the generator is ready for use by running it monthly.

Transferring to Generator Power

Procedure for switching from utility power to generator power.

Transferring back to Utility Power

Procedure for switching back from generator to utility power.

Specifications

Five Year Limited Warranty