OOO Neomatica. Terminal ADM007 GLONASS / GPS. Rev.1.3 dated 13.09.2019
19
GPRS:
APN=internet.mts.ru,
user=mts, pass=mts
10
SETHOST0 X,Y
Example:
SETHOST0
134,236,21,2,12300
HOST0=X,Y
Example:
HOST0=134.236.21.2:1230
0
Configuring the IP address and port of the server to
which the tracker connects to transmit information. A
command without parameters returns the current server
address and port.
11
DN0 X:Y
Example:
DN0 www.test.ru:1000
HOST0=X:Y
Example:
HOST0= www.test.ru:1000
Configure the domain name and port of the server to
which the tracker connects to transmit information. A
command without parameters returns the current server
address and port.
12
ERASE FLASH
ERASE FLASH
Erase all information packets stored in memory. After
executing this command, the current information packet
number is reset, the tracker is rebooted.
13
ERASE EEPROM
ERASE EEPROM
Restore the tracker's factory settings and restart the
tracker.
14
PERIOD X,Y
Example:
PERIOD 20,120
PERIOD min=X, max=Y
Example:
PERIOD min=20, max=120
Set the recording period in the memory of information
packets during driving and parking.
A command without parameters returns the current
settings.
15
TRACKSET X
The response displays
a detailed
configuration of all set
parameters of the
travel path
Select the preset of the travel path drawing
quality. More details see in clause 5.5.1
Selecting presets of route drawing quality
16
InTrue X,Ymin,Ymax
Example:
InTrue 0,10000,60000
InTrue X,Ymin,Ymax
Example:
InTrue 0,10000,60000
Set the voltage range of the logical unit on the analog
input.
17
InFalse X,Ymin,Ymax
Example:
InFalse 0,0,4000
InFalse X,Ymin,Ymax
Example:
InFalse 0,0,4000
Set the voltage range of logical zero on the analog input.
18
InInfo X
Example:
InInfo 0
Example: Input 0: InTrue
8000..15000, InFalse
0..3000
Request information about the input settings.
19
INPUT
INPUT0 = 12000
Query the current measured voltage level at the analog
input (mV).