EasyManua.ls Logo

Neomitis RT7 RF - Troubleshooting and Specifications; Factory Settings Restoration; Common Troubleshooting Issues; What is a Room Thermostat

Neomitis RT7 RF
4 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Registered trademarks - All rights reserved
NEOMITIS
®
LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London WC1V 7JH
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contact_uk@neomitis.com
Creating innovative solutions for ambient comfort
www.neomitis.com
The boiler is not heating:
-CheckthattheThermostatiscallingforheatifyesthenthethermostatwould
appeartobeworkingcheckthattheboilerhasnotswitcheditselfoff.
If no increase set temperature.
-Checkthepositionofthebatteries.Removethemfor30secondsand
reinsertthem.Iftheproblempersists,replacethe2batteries.
Nothing in the display:
-Checkthepositionofthebatteries.Removethemfor30secondsand
reinsertthem.Iftheproblempersists,replacethe2batteries.
The room temperature is not high enough, the boiler is not providing
enough heat:
- Check the active operating mode (seepage3) - the room thermostat
maybeinanEco,StandbyorAutoModeentailingatemperaturedrop.
- Check the active desired temperature and increase it if need be (see
page 2).
The temperature in the room is lower than the setpoint temperature:
-Checktheprogramming.ThethermostatcouldbeinascheduledEco
period.
-Ensurethatthetimedisplayedisthesameasthecurrenttime.
You made a mistake while setting:
-You just need to restore factory settings, as explained in the “Factory
settings” section (seepage3).Thiswillreverseanychangesyoumight
have made.
The system is not heating but
is on:
- If andindicatorlightisonbutthesystemremainscold,thenyoushould
contactyourinstaller.
If the problem persists, then contact your installer.
TROUBLESHOOTING
...anexplanationforhouseholders
A room thermostatsimply switches
the heating system on and off as
necessary. It works by sensing the
air temperature, switching on the
heating when the air temperature
falls below the thermostat setting,
and switching it off once this set
temperature has been reached.
Turning a room thermostat to a hi
-
ghersettingwillnotmaketheroom
heatupanyfaster.Howquicklythe
room heats up depends on the design of the heating system, for exa
-
mple,thesizeofboilerandradiators.Neitherdoesthesettingaffecthow
quicklytheroomcoolsdown.
Turningaroomthermostattoalowersettingwillresultintheroombeing
controlledatalowertemperature,andsavesenergy.
Theheatingsystemwillnotworkifatimeswitchorprogrammerhasswit
-
ched it off. Theway to setand use yourroom thermostat isto nd the
lowesttemperaturesettingthatyouarecomfortablewith,andthenleave
italonetodoitsjob.Thebestwaytodothisistosettheroomthermostat
toalowtemperature–say18ºC–andthenturnitupbyonedegreeeach
dayuntilyouarecomfortablewiththetemperature.Youwon’thaveto
adjustthethermostatfurther.Anyadjustmentabovethissettingwillwaste
energy and cost you more money.
Ifyourheatingsystemisaboilerwithradiators,therewillusuallybeonly
oneroomthermostattocontrolthewholehouse.Butyoucanhavediffe
-
rent temperatures in individualrooms by installingthermostatic radiator
valves(TRVs) onindividualradiators.If youdon’thaveTRVs,you should
chooseatemperaturethatisreasonableforthewholehouse.Ifyoudo
have TRVs, you can choose a slightly higher setting to make sure that
eventhecoldestroomiscomfortable,thenpreventanyoverheatingin
other rooms by adjusting the TRVs.
Roomthermostats need a freeowof air to sensethe temperature,so
they must not be covered by curtains or blocked by furniture. Nearby
electricres,televisions,wallortablelampsmaypreventthethermostat
fromworkingproperly.
WHAT IS A ROOM THERMOSTAT
Pleaserefertotheinstallinginstructionsforanyinformationsaboutbatte-
rieslife,standardsandproductenvironment.
TECHNICAL SPECIFICATIONS
FACTORY SETTINGS
AllLCDdisplaywillbeturnedONfor2secondsandthefactorysettings
willberestored.
Note:Torestorefactorysettings,pressandholddownthispartformore
than3secondsusingthetipofapen.
am
Tu
C
C
Settings Factory settings
Comfort temperature
20°C
Eco temperature
10°C
Comfort period 1 Startat06:30
am
Endat08:30
am
Comfort period 2 Start at 12:00
pm
End at 02:00
pm
Comfort period 3 Start at 05:00
pm
End at 10:00
pm

Related product manuals