Meter Size (In)
Maximum
Continuous
Flow Rate
(gpm)
Minimum Flow
Rate (gpm)
Number of Pulses per
Gallon*
Pulse Output @
Maximum Flow
Rate (Hz)*
Flow Range of
4-20MA
Output (gpm)
160 4 6.09500 16.25 0–160
2 200 4 6.09500 20.32 0–200
3 450 5 11.20000 84.00 0–450
4 1,200 10 7.55600 151.1 0–1,200
6 2,500 20 0.72730 30.30 0–3,000
8 4,000 35 0.75560 50.37 0–4,000
10 6,500 50 0.75560 81.86 0–6,500
12 8,000 120 0.75560 100.75 0–8,000
16 13,500 200 0.07556 17.00 0–13,500
20 22,000 300 0.07556 27.71 0–22,000
Table 8 – High Performance Turbine (HPT) Meters
*For the High Resolution Output of the TRICON/E2 transmitters, multiply these values by 9 and for the
TRICON/E3, multiply these values by 10.
TRICON
®
E/E2/E3 Installation and Maintenance Guide 7
Chapter 2: Specifications