Troubleshooting
If the TRICON appears to be operating, but electronic flow indication does not agree with
mechanical register indication, try the troubleshooting steps in the following table.
Verify that the... If not, then...
TRICON and register match the meter size and type. Replace the TRICON or the register with the appropriate
type to match the meter.
Register turns smoothly when installed on the TRICON. Replace the register or have it repaired to correct
problems with excessive torque.
TRICON is wired and powered properly. Correct the wiring or power problem.
Compatibility and proper calibration of equipment to
which the TRICON is connected.
Adjust and calibrate the equipment as required.
Table 12 – Troubleshooting the TRICON
®