(Can only be done in Master Programming Mode)
Three programming options for Door Access Control are provided; Card Only, Card AND PIN or Card OR PIN
6.1 Grant Access by Card Only
6.2 Grant Access by Card AND PIN
6.3 Grant Access by Card OR PIN (Factory Default )
(Can only be done in Master Programming Mode)
This option sets the activation time of the Relay when Access is granted by Card or PIN
(Can only be done in Master Programming Mode)
These options are used to Enable / Disable the “D_In” (Door Switch Input).
Disables the Door Open Detection
Enables the Door Open Detection
When enabled:
If the door is opened normally but not closed within 1 minute the buzzer will sound for 1 minute
If the door is forced open (opened by an unauthorized user) the buzzer and alarm output will be activated
(Can only be done in Master Programming Mode)
Three options are provided for programming Keypad Lockout / Alarm Output in the event that multiple invalid
Access attempts are made. Programming any option will override all previous settings
(No Alarm Output or Keypad Lockout)
When enabled, the number of keypad entries is unrestricted (no Alarm Output or Keypad lockout regardless of
the number of invalid code entries)
When enabled, the Keypad will lockout for 10 minutes if there are 10 successive invalid card presentations or 10
successive incorrect PIN numbers entered within a 10 minute period