OIL FLOW ADJUSTMENT
Correction of the maximum flow. The
flame must not cause soot or rumbling.
Exact adjustment can be carried out only
when a device for measuring the soot is
available.
Correction of the minimum flow. The
flame must just burn all round in the case
of minimum flow.
Note: the high flame must first be
controlled or adjusted, then the low
flame.
Removal of the complete lid assembly.
Removal of the metering stem.