NETAFLEX™ 3G USER MANUAL
29
System pump list
For 50 Hz installations
SPARE PARTS
For 60 Hz installations
Pump Electrical data
CM 10-3
Rated power: P2: 2.2 kW
Rated voltage: 3 x 230/400Y V
Nominal current: 8.15/4.7 A
Consumption*: 2.35 kW
CM 10-4
Rated power: P2: 3.2 kW
Rated voltage: 3 x 230/400Y V
Nominal current: 11.8/6.75 A
Consumption*: 3.35 kW
CM 25-2
Rated power: P2: 4 kW
Rated voltage: 3 x 230/400Y V
Nominal current: 14.0/8.2 A
Consumption*: 4.15 kW
CM 25-3
Rated power: P2: 5.8 kW
Rated voltage: 3 x 230/400Y V
Nominal current: 20.4/11.8 A
Consumption*: 5.95 kW
CR 32-3-2
Rated power: P2: 5.5 kW
Rated voltage: 3 x 400∆ V
Nominal current: 11.0 A
Consumption*: 5.65 kW
CR 32-3
Rated power: P2: 5.5 kW
Rated voltage: 3 x 400∆ V
Nominal current: 11.0 A
Consumption*: 5.65 kW
CR 45-2
Rated power: P2: 11 kW
Rated voltage: 3 x 400∆ V
Nominal current: 20.8 A
Consumption*: 7.65 kW
CR 45-3-2
Rated power: P2: 11 kW
Rated voltage: 3 x 400∆ V
Nominal current: 14.4 A
Consumption*: 11.15 kW
CR 64-2-1
Rated power: P2: 11 kW
Rated voltage: 3 x 400∆ V
Nominal current: 20.8 A
Consumption*: 11.15 kW
CR 64-2
Rated power: P2: 11 kW
Rated voltage: 3 x 400∆ V
Nominal current: 20.8 A
Consumption*: 11.15 kW
* Total power consumption of the NetaFlex™ 3G with the mentioned system pump, the controller,
the dosing valves, etc.
Pump Electrical data
CM 10-2
Rated power: P2: 2.5 kW
Rated voltage: 3 x 220∆/440Y V
Nominal current: 8.95/4.3 A
Consumption*: 2.65 kW
CM 10-3
Rated power: P2: 4 kW
Rated voltage: 3 x 220∆/440Y V
Nominal current: 14.8/7.2 A
Consumption*: 4.15 kW
CM 15-2
Rated power: P2: 4 kW
Rated voltage: 3 x 220∆/440Y V
Nominal current: 14.8/7.2 A
Consumption*: 4.15 kW
CM 25-2
Rated power: P2: 6 kW
Rated voltage: 3 x 220∆/440Y V
Nominal current: 21.0/10.5 A
Consumption*: 6.15 kW
CR 32-2-2
Rated power: P2: 5.5 kW
Rated voltage: 3 x 440∆ V
Nominal current: 10.6 A
Consumption*: 5.65 kW
CR 32-2
Rated power: P2: 7.5 kW
Rated voltage: 3 x 440∆ V
Nominal current: 14.2 A
Consumption*: 7.65 kW
CR 45-2-2
Rated power: P2: 11 kW
Rated voltage: 3 x 440∆ V
Nominal current: 20.8 A
Consumption*: 11.15 kW
CR 45-1
Rated power: P2: 7.5 kW
Rated voltage: 3 x 440∆ V
Nominal current: 14.2 A
Consumption*: 7.65 kW
CR 64-1
Rated power: P2: 11 kW
Rated voltage: 3 x 440∆ V
Nominal current: 20.8 A
Consumption*: 11.15 kW
CR 64-2-2
Rated power: P2: 15 kW
Rated voltage: 3 x 440∆ V
Nominal current: 28.0 A
Consumption*: 15.5 kW