If the
Key Manager type = external and the Restored column = anything other than yes/true,
use the
security key-manager external restore command to restore the key IDs of the
authentication keys.
If the command fails, contact Customer Support.
â—¦
If the
Key Manager type = onboard and the Restored column = anything other than yes/true,
use the
security key-manager onboard sync command to re-sync the Key Manager type.
Use the
security key-manager key query command to verify that the Restored column =
yes/true for all authentication keys.
11. Connect the console cable to the partner controller.
12.
Give back the controller using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - AFF A250
Return the failed part to NetApp, as described in the RMA instructions shipped with the
kit. See the
Part Return & Replacements page for further information.
Chassis
Overview of chassis replacement - AFF A250
To replace the chassis, you must move the bezel, controller modules, and NVMe drives
from the impaired chassis to the replacement chassis, and then remove the impaired
chassis from the equipment rack or system cabinet and install the replacement chassis in
its place.
About this task
• All other components in the system must be functioning properly; if not, you must contact technical support.
• You can use this procedure with all versions of ONTAP supported by your system.
• This procedure is written with the assumption that you are moving the bezel, NVMe drives, and controller
modules to the new chassis, and that the replacement chassis is a new component from NetApp.
• This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a partial
outage in a multi-node cluster.
Shut down the controllers - AFF A250
This procedure is for 2-node, non-MetroCluster configurations only. If you have a system
with more than two nodes, see
How to perform a graceful shutdown and power up of one
HA pair in a 4-node cluster
.
Before you begin
You need:
257

Other manuals for NetApp AFF A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp AFF A Series and is the answer not in the manual?

NetApp AFF A Series Specifications

General IconGeneral
BrandNetApp
ModelAFF A Series
CategoryServer
LanguageEnglish

Related product manuals