EasyManuals Logo

NetApp AFF A Series User Manual

NetApp AFF A Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #260 background imageLoading...
Page #260 background image
• Local administrator credentials for ONTAP.
• NetApp onboard key management (OKM) cluster-wide passphrase if using storage encryption.
• SP/BMC accessability for each controller.
• Stop all clients/host from accessing data on the NetApp system.
• Suspend external backup jobs.
• Necessary tools and equipment for the replacement.
If the system is a NetApp StorageGRID or ONTAP S3 used as FabricPool cloud tier, refer to the
Gracefully shutdown and power up your storage system Resolution Guide after performing this
procedure.
If using FlexArray array LUNs, follow the specific vendor storage array documentation for the
shutdown procedure to perform for those systems after performing this procedure.
If using SSDs, refer to SU490: (Impact: Critical) SSD Best Practices: Avoid risk of drive failure
and data loss if powered off for more than two months
As a best practice before shutdown, you should:
• Perform additional
system health checks.
• Upgrade ONTAP to a recommended release for the system.
•
Resolve any
Active IQ Wellness Alerts and Risks.
Make note of any faults presently on the system, such as LEDs on the system components.
Steps
1. Log into the cluster through SSH or log in from any node in the cluster using a local console cable and a
laptop/console.
2. Turn off AutoSupport and indicate how long you expect the system to be off line:
system node autosupport invoke -node * -type all -messages "MAINT=8h Power
Maintenance"
3. Identify the SP/BMC address of all nodes:
system service-processor show -node * -fields address
4.
Exit the cluster shell:
exit
5. Log into SP/BMC over SSH using the IP address of any of the nodes listed in the output from the previous
step.
If your’re using a console/laptop, log into the controller using the same cluster administrator credentials.
Open an SSH session to every SP/BMC connection so that you can monitor progress.
6. Halt all nodes in the cluster:
system node halt -node * -skip-lif-migration-before-shutdown true -ignore
-quorum-warnings true -inhibit-takeover true.
258

Other manuals for NetApp AFF A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp AFF A Series and is the answer not in the manual?

NetApp AFF A Series Specifications

General IconGeneral
BrandNetApp
ModelAFF A Series
CategoryServer
LanguageEnglish

Related product manuals