failures resulting from testing the component.
7. Proceed based on the result of the preceding step.
If the system-level diagnostics tests… Then…
Were completed without any failures a.
Clear the status logs:
sldiag device
clearstatus
b.
Verify that the log was cleared:
sldiag device
status
The following default response is displayed:
SLDIAG: No log messages are
present.
c.
Exit Maintenance mode on both controllers:
halt
The system displays the LOADER prompt.
You must exit Maintenance mode
on both controllers before
proceeding any further.
d. Enter the following command on both controllers
at the LOADER prompt:
bye
e. Return the controller to normal operation.
If your system is running ONTAP… Then…
With two nodes in the cluster
Issue these commands: node::> cluster ha
modify -configured true``node::>
storage failover modify -node node0
-enabled true
With more than two nodes in the cluster
Issue this command:node::> storage failover
modify -node node0 -enabled true
In a stand-alone configuration
You have no further steps in this particular task.
You have completed system-level diagnostics.